Key Features Include:
- New with V 1.1 Upgrade! Zoom on trend provide unprecedented ability to view
analyze TrendCapture data; see detail at X5 magnification.
- New with V 1.1 Upgrade! Simplified Record screen when setting up recording
- New with V 1.1 Upgrade! Logging function with expanded memory for unattended
monitoring of signals over time. Using on-board TrendCapture users can
graphically review logged readings without needing a PC. Store up to 15,000
recorded events.
- Large 50,000 count, ¼ VGA display with white backlight. Multiple sets of
measurement information can simultaneously be displayed at the same time.
- Logging function with TrendCapture is an essential tool for documenting the
performance of your designs, processes or systems, or unattended monitoring
while you work on other projects. It plots measurements as a single line to help
detect signal anomalies over time. Using on-board TrendCapture, you can
graphically view logged readings without a PC. (Software and interface cable
optional).
- Log multiple sessions or log data continuously for over 200 hours.
- i-info button. On board help screens for measurement functions. Unsure about
a function? Go to that function and Press the “i” button.
- Now, name your saved measurements and also recall measurements made in the
field
- Real Time Clock – for automatic time stamping of saved readings
- Field upgradeable and expandable meter lets you stay current as new
capabilities are added
- Multi-lingual interface
- Min/Max/Average with Time Stamp to record signal fluctuations
- Soft keys, scroll buttons and easy navigation control access to secondary
functions.
- 0.025% Basic DC accuracy
- 100 kHz ac bandwidth
- True-rms ac voltage and current for accurate measurements on complex signals
or non-linear loads.
- Measure up to 10A (20 A for 30 seconds; 10A continuous)
- 100 mF capacitance range
- Temperature function
- Relative mode to remove test lead resistance from low ohms or capacitance
measurements
- Peak capture to record transients as fast as 250 μs
- Premium test leads and alligator clips included
- Optional FlukeView forms enables you to document, store and analyze
individual readings or a series of measurements, then convert them into
professional-looking documents
- Optional magnetic hanger allows you to hang the meter for easy viewing while
freeing your hands to focus on the job.
- Limited lifetime warranty
- CAT III 1000 V / CAT IV 600 V safety rated
| Specifications |
| Voltage DC |
| Accuracy |
0.025 % |
| Range and Resolution |
50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V,
1000.0V |
|
| Voltage AC |
| Accuracy |
0.4 %(true-rms) |
| Range and Resolution |
50.000 mV,500.00 mV, 5.0000 V, 50.000 V, 500.00 V,
1000.0V |
|
| Current DC |
| Accuracy |
0.06 % |
| Range and Resolution |
500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000
A |
|
| Current AC |
| Accuracy |
0.6%(true-rms) |
| Range and Resolution |
500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000
A |
|
| Temperature (excluding probe) |
| Accuracy |
1.0 % |
| Range and Resolution |
-200.0 °C to 1350.0 °C (-328.0 °F to 2462.0
°F) |
|
| Resistance |
| Accuracy |
0.05 % |
| Range and Resolution |
500.00 &, 5.0000 k&, 50.000 k&, 500.00 k&, 5.0000 M&, 50.00 M&, 500.0
M& |
|
| Capacitance |
| Accuracy |
1.0 % |
| Range and Resolution |
1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00
mF, 100.00 mF |
|
| Frequency |
| Accuracy |
0.005% + 5 |
| Range and Resolution |
99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99
kHz |
|
| Additional functions/features |
| Multiple on-screen displays |
Yes |
| True-rms AC bandwidth |
100 kHz |
| DBV/dBm |
Yes |
| Conductance |
50.00nS |
| Continuity beeper |
Yes |
| Battery/Fuse access |
Battery / Fuse |
| Peak |
250 μS |
| Elapse time clock |
Yes |
| Time of day clock |
Yes |
| Min-Max-Avg |
Yes |
| Duty Cycle |
0.01 % to 99.99 % |
| Pulse Width |
0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms |
| Hold |
Yes |
| Isolated Optical Interface |
Yes |
| Auto/Touch Hold |
Yes |
| Reading memory |
Yes |
| Log to PC |
Yes |
| Interval/Event Logging |
Yes |
| Logging Memory |
Up to 10,000 readings |
|
| Environmental Specifications |
| Operating Temperature |
|
| Storage Temperature |
|
| Relative Humidity |
|
0% to 90% (0 °C - 37 °C) |
|
0% to 65% (37 °C - 45 °C), |
|
0 to 45 % (45 °C - 55 °C |
|
| Electromagnetic Compatability |
|
| Vibration |
|
Random vibration per MIL-PRF-28800f Class
2 |
|
| Shock |
|
1 meter drop per IEC/EN 61010-1 2nd
edition |
|
| Safety Specifications |
| Overvoltage category |
|
CAT III 1000 V / CAT IV 600 V safety
rated |
|
| Agency Approvals |
|
| Mechanical & General
Specifications |
| Maximum voltage between any terminal and earth
ground |
|
| Size |
|
(HxWxL 22.2 cm x 10.2 cm x 6 cm (8.75 in x 4.03 in x 2.38
in) |
|
| Weight |
|
| Battery Life |
|
100 minimum, 200 hours in logging mode |
|
| Battery type |
|
6 AA alkaline batteries, NEDA 15A IEC LR6 |
|
|
|
You may also be interested in this/these product(s)
FLUKE T5-1000 DIGITAL ELECTRICAL TESTER
|
FLUKE H5 HOLSTER WITH BELT LOOP
|
FLUKE 80PK-22 SUREGRIP IMMERSION TEMPERATURE PROBE
|
FLUKE C50 METER CARRYING CASE
|
|
|
|
|
|
|
|
|
|
Random Products |
STANLEY 33-158 POWER LOCK MEASURING TAPE 5M
|
SRI FIRE HOSE REEL 25MM X 30M
|
MAKTEC MT920 FINISHING SANDER
|
MAKITA 4107R CUTTER 1400W
|
HOZELOCK 7230S MAXI PLUS HOSE 30M WITH STARTER SET
|
|
|
|